What should you use to count people entering and leaving a building?

Plan entrance and exit measurement with Density Entry, from doorway coverage to health-aware workplace analytics.

Illustration of people arriving and leaving through a building entrance.

Density Entry measures entrances and exits used to calculate occupancy across a defined building or floor. These counts let a workplace team examine how busy a building becomes, when occupancy peaks and how use changes over time.

Start with the boundary you want to measure. A building, a floor and a room have different entrances. Your counting plan should account for every route across the chosen boundary.

Entrances, exits and occupancy answer different questions

An entrance is a crossing into the measured space. An exit is a crossing out. Occupancy is a running count of people present, calculated from a starting count plus entrances minus exits. Density explains this relationship in its Entry occupancy documentation.

In this hypothetical example, a floor starts with 12 people. During the next hour, 70 people enter and 45 leave:

12 + 70 − 45 = 37 people remaining.

The 70 entrances describe incoming traffic. The resulting 37 describes occupancy at the end of that interval. Neither number alone tells you the busiest moment within the hour. Preserve the timing of observations when evaluating peak demand.

Use entrance totals to examine arrival patterns; use occupancy over time to examine concurrent demand for space.

How do people-counting sensors compare with badge data and Wi-Fi analytics?

Density Entry supplies directional counts across a covered boundary. Badge and network records can add context, but first establish what each record measures.

A badge record describes a credential event at a reader. If your system records entrances without corresponding departures, an access total cannot supply the running occupancy calculation by itself. Density's badge-data guide explains why access records and space-use decisions need different evidence. Review the actual access configuration, visitor treatment and coverage before comparing its totals with counts.

Client-based Wi-Fi analytics starts from observations of devices. Cisco Meraki's Location Analytics documentation defines its visitors as wireless devices and describes version-specific handling of randomized identifiers. Ask how the proposed system turns device observations into a people estimate; that rule is part of the comparison.

Extend the hypothetical example above. A report of 70 incoming credential events still needs a starting count and departures before it can support an occupancy estimate. A network report of 40 devices does not automatically establish 40 people in the space.

Compare the records within the same boundary and time window. Use Entry's directional counts to measure people, access events to understand credential use and client-device observations to understand devices. Label those units beside the chart.

Prepare the doorway plan before installation

Density's Entry installation guide calls for sensor coverage above every entryway to the measured space and specifies indoor use. Build the deployment around that coverage requirement:

  • Define the space. Mark the building, floor or other boundary on a floor plan.
  • Map every crossing. Include staff entrances and connecting routes, not just the main lobby.
  • Document each threshold. Record doorway width, mounting conditions and objects that could obstruct the sensing area.
  • Review the placement. Use the applicable installation guidance and have Density confirm the arrangement for your entryways.

Density's pre-installation assessment provides the next level of planning detail. A complete doorway plan makes the resulting space count easier to interpret.

Match the count to the landlord’s question

Consider a hypothetical building with two leased floors and a shared lounge. With full coverage of the measured boundary, building occupancy describes how many people are inside. A separately measured floor count includes everyone present on that floor, including visitors and service workers. A lounge count describes use of the lounge; it does not identify which tenant employs the people using it.

Density’s Building Analytics guide distinguishes occupancy from entrance visits and explains that anonymous readings are not employee-filtered. Choose boundaries around the space decision: building occupancy, floor occupancy or shared-amenity use. Keep those readings separate from tenant employee-attendance records, and do not add a lounge’s occupants to a building total that already includes them. Have Density review every route across the proposed Entry boundaries and the appropriate measurement method for the lounge.

Agree on reset and drift handling

Entry-based occupancy accumulates crossings. A difference between recorded entrances and exits can carry into the running count; Density calls that offset drift.

The March 2026 support guidance describes an overnight reset selected during implementation. Choose a reset window when the measured space is empty, accounting for cleaners and night staff. For historical reporting, Density’s drift-correction guidance describes correction at query time, applied after the daily reset. Use the live running total for current occupancy and the appropriate historical result for a retrospective planning review.

Retain counts during a network interruption

Density's Entry local-storage guidance describes a useful distinction between losing connectivity and losing power. An Entry sensor that remains fully powered while offline stores data locally for approximately 28 days, depending on traffic volume, or until its memory is full. It uploads the historical data when the network connection returns.

That supports historical continuity while the sensor can keep counting. It does not make those readings available to a live application during the disconnection. If the sensor loses consistent power, it cannot count during that period. Keep power and connectivity as separate checks in the operating plan, then review the historical record after reconnection. This storage guidance applies to Entry; confirm recovery behavior separately for other sensor models.

Connect the count to workplace analytics

Give each count a clear space, timestamp and health context. Density's API reference documents occupancy updates through a WebSocket endpoint. Its health guidance distinguishes a valid space reading from unavailable data; an offline reading should not become an empty-building assumption.

For a planning review, keep the space boundary, reporting hours and comparison period consistent. Compare busy periods as well as averages. Then connect the observed pattern to a decision, such as whether the building can accommodate another team's attendance.

Bring Density the boundary you want to understand and the decision you need to make. Book a demo or email sales@density.io to plan your Entry deployment.

For the next step after doorway planning, read the occupancy API guide. Use the simultaneous-peak example before combining counts from separate spaces.

Browse occupancy guides and sensor comparisons · Read the plain-text version

Tags:

Table of Contents

Key Takeaways

DisruptCRE founder shares how corporate real estate is changing

DisruptCRE founder shares how corporate real estate is changing

Companies are moving employees from underutilized offices into "space as a service” options with utilization data.

Watch now

Most recent

What is a good office space utilization rate?

What is a good office space utilization rate?

A useful utilization target depends on the space, denominator and busiest-day needs. Learn how to set a target your workplace can act on.

Looking for an occupancy analytics platform to optimize your office space?

Looking for an occupancy analytics platform to optimize your office space?

Choose a platform around the space decision, sensor coverage and reporting workflow. Use a practical pilot to test the evidence before a rollout.

How do you manage hot desking in a hybrid office?

How do you manage hot desking in a hybrid office?

Plan shared desks around actual demand, make the rules easy to follow, and measure availability alongside employee experience.

How can radar sensors help optimize office space?

How can radar sensors help optimize office space?

Measure how rooms and desk neighborhoods are used, test a layout change, and compare results before committing to a larger redesign.

Explore other Density Products

Atlas

A visual insights dashboard that tells you how your space is performing.

Learn more

Atlas for Workplace

Insights for the workplace that help you cut costs and deliver better spaces.

Learn more

Live Wayfinding

A real-time map of available spaces, built for employees.

Learn more

Density Advisory

Your partner in turning complex workplace data into actionable strategy.

Learn more